Page 22 - Catalog
P. 22
NITROTEL PRODUCT INFORMATION STRUCTURED CABLING STRUCTURED CABLING NITROTEL PRODUCT INFORMATION & PATCH CABLE LAN CABLE
STRUCTURED CABLING STRUCTURED CABLING
PATCH CORD PATCH CORD
SF/UTP double fully shielded twisted airs U/UTP unshielded twisted airs ategory 6 FACE PLATE
d
ategory E sli at h ord flat at h ord
Braid
PET
Copper Conductor
HDPE Insulation MODULES
Pair
Jacket
Aluminum Foil Jacket
Copper Conductor
HDPE Insulation
Pair Conductor
Standard
Conductor stranded bard copper 32AWG
Electrical performance guaranteed to meet or exceed Insulation HDPE
Standard
ANSI/TIA-568.2-D Category 5e and ISO/EIC specifications. Total number of 8, twisted in 4 pairs
Independently tested and verified UL. Electrical performance guaranteed to meet or exceed insulated conductors
Ideal for Data center architectural requirements. ANSI/TIA-568.2-D Category 6 and ISO/EIC specifications. Color code blue x white, orange x white,
green x white, brown x white
Stranded cable for maximum flexibility. Independently tested and verified UL. Individual pair shield None
Available with different plug mold. Ideal for Data center architectural requirements. Overall shield None
Available with different color of cable. Stranded cable for maximum flexibility. Drain wire None PATCH PANELS
Available with different lengt. Available with different plug mold.
Available with different color of cable. rder in ormation ( art N m er
Available with different lengt.
Conductor NTFPC6E_ _ _ _
rder in ormation ( art N m er
Conductor stranded bard copper 28AWG
NTPC5E_ _ _ _ SFTPSL Available Length Jacket Color
Insulation HDPE
YL
RD
Total number of 8, twisted in 4 pairs 01 02 03 BU WH
insulated conductors Available Length Jacket Color 05 07 10 OR
BK
White-Blue/Blue,White-Orange/Orange 01 02 03 GY GN
YL
RD
Color code BU WH 15 25 50
White-Green/Green,White-Brown/Brown
05 07 10
Individual pair shield None GY GN OR Special orders available upon request.
BK
15 25 50 Nominal Transmission Characteristics
Aluminum foil, providing 100%
Overall shield
coverage, foil face out. Special orders available upon request.
Prop.
PS
PS
Drain wire None Res. Length Delay Delay Freq. Insertion NE T RL ACR-N ACR-F PS NE T ACR-N ACR-F
Loss
Skew
Ω Max. n s ns & XPON OPTICAL FIBER
Nominal Transmission Characteristics i 20m 555 50 1 3 65.0 19.0 62.0 63.3 62.0 59.0 60.3
4 4 63.0 19.0 59.0 51.2 60.5 56.5 48.2
Prop. Delay Insertion PS PS
Res. Length Freq. NE T RL ACR-N ACR-F PS NE T 8 5.7 58.2 19.0 52.5 45.2 55.6 49.9 42.2
Delay Skew Loss ACR-N ACR-F
10 6.3 56.6 19.0 50.2 43.3 54.0 47.7 40.3
Ω Max. n s ns 16 8 53.2 18.0 45.2 39.2 50.6 42.6 36.2
i 100m 555 50 1 3 60.0 17.0 57.0 57.4 57.0 54.0 54.4
20 9 51.6 17.5 42.6 37.2 49.0 39.9 34.2
4 4.5 53.5 17.0 49.1 45.4 50.5 46.1 42.4 25 10.1 50.0 17.0 39.9 35.3 47.3 37.2 32.3
8 6.3 48.6 17.0 42.3 39.3 45.6 39.3 36.3
31.25 11.4 48.4 16.5 37.0 33.4 45.7 34.3 30.4
10 7.1 47.0 17.0 39.9 37.4 44.0 36.9 34.4
62.5 16.5 43.4 14.0 26.9 27.3 40.6 24.1 24.3
16 9.1 43.6 17.0 34.5 33.3 40.6 31.5 30.3 100 21.3 39.9 12.0 18.6 23.3 37.1 15.8 20.3
20 10.2 42.0 17.0 31.8 31.4 39.0 28.8 28.4
200 31.5 34.8 9.0 3.3 17.2 31.9 0.3 14.2
25 11.4 40.3 16.0 28.9 29.4 37.3 25.9 26.4
250 35.9 33.1 8.0 -2.8 15.3 30.2 -5.8 12.3
31.25 12.9 38.7 15.1 25.9 27.5 35.7 22.9 24.5
62.5 18.6 33.6 12.1 15.0 21.2 30.6 12.0 18.5 CABINETS
100 24 30.1 10.0 6.1 17.4 27.1 3.1 14.4
page 033 page 034