Page 51 - Catalog
P. 51

NITROTEL PRODUCT INFORMATION    STRUCTURED CABLING                                                                                                            STRUCTURED CABLING    NITROTEL PRODUCT INFORMATION     & PATCH CABLE  LAN CABLE



                      STRUCTURED CABLING                                                                                                               STRUCTURED CABLING




                      OPTICAL FIBER                                                                                                                                             OPTICAL FIBER






                       Stranded Loose Tube Cable with Steel Ta e  G TS                                                                            Stranded Loose Tube Cable with Alu inu  Ta e  G TA                                        FACE PLATE




                                                                    Fig 1                                                                                                              Fig 1
                                                                                                                                         Introduction
                       Introduction                                                               PE Sheath                                                                                                         PE Sheath
                                                                                                                                        In the Nitrotel GYTA cable, single-mode/multimode fibers are
                                                                                                                                                                                                                       APL
                       In the Nitrotel GYTS cable, single-mode/multimode fibers are                  PSP                                positioned  in  the  loose  tubes,  which  are  made  of  high                 Fiber
                       positioned  in  the  loose  tubes,  which  are  made  of  high                Fiber                              modulus  plastic  materials,  while  the  loose  tubes  strand
                       modulus  plastic  materials,  while  the  loose  tubes  strand      Tube  lling compound                         together  around  metallic  central  strength  member  into  a       Tube  lling compound
                       together  around  metallic  central  strength  member  into  a             Loose tube                            compact and circular cable core. For certain high fibre count              Loose tube
                       compact and circular cable core. For certain high fiber count          Strength Member                           cables,  the  strength  member  would  be  covered  with                Strength Member
                       cables,  the  strength  member  would  be  covered  with           Cable Filling Compound                        polyethylene  (PE).  The  water-blocking  materials  are            Cable Filling Compound
                       polyethylene  (PE).  The  water-blocking  materials  are                                                         distributed  into  interstices  of  the  cable  core,  and  the
                       distributed into interstices of the cable core, and the PSP is                                                   Aluminum  Polyethylene  Laminate  (APL)  is  longitudinally
                       longitudinally applied around the cable core before a HDPE                                                       applied  around  the  cable  core  before  a  HDPE  sheath  is
                       sheath is extruded over it.                                                                                      extruded over it.                                                                                   MODULES
                                                                                                                                         Fiber color code
                       Fiber color code                                         9     10     11                                            1      2      3     4      5      6      7      8      9     10     11     12
                         1      2      3      4     5      6      7      8                          12
                                                                                                                                          Blue  Orange  Green  Brown  Gray  White  Red    Black  Yellow  Violet  Pink  Aqua
                        Blue  Orange  Green  Brown  Gray  White  Red    Black  Yellow  Violet  Pink  Aqua
                                                                                                                                         Fiber color in each tube starts from No. 1 Blue.
                        Fiber color in each tube starts from No. 1 Blue.
                                                                                                                                         Color codes for loose tube    ller rod
                       Color codes for loose tube    ller rod                   9     10     11                                            1      2      3     4      5      6      7      8      9     10     11     12
                         1      2      3      4     5      6      7      8                          12                                    Blue  Orange  Green  Brown  Gray  White  Red    Black  Yellow  Violet  Pink  Aqua
                        Blue  Orange  Green  Brown  Gray  White  Red    Black  Yellow  Violet  Pink  Aqua                                Tube color in each layer starts from No. 1 Blue. If there are  llers, the color is nature.
                        Tube color in each layer starts from No. 1 Blue. If there are  llers, the color is nature.
                                                                                                                                        Order Information and Characteristics of Optical Cables
                      Order Information and Characteristics of Optical Cables                                                               Cable Type             Tube  Max. No. of  Cable   Cable   Tensile Strength  Crush Resistance
                                                                                                                                                        Fiber Count       Fibers in  Diameter  Weight  Long/ShortTerm  Long/ShortTerm       PATCH PANELS
                                                 Tube  Max. No. of  Cable   Cable   Tensile Strength  Crush Resistance                    (increased by 2  bers)
                           Cable Type                                                                                                                             Fillers  each Tube  mm   kg/km      N         N/100 mm
                                      Fiber Count       Fibers in  Diameter  Weight  Long/ShortTerm  Long/ShortTerm
                       (increased by 2  bers)                                                                                              NT-GYTA-2~30 n  2~30     5       6      9.2      85     600/1500      300/1000
                                                 Fillers  each Tube  mm  kg/km      N          N/100 mm
                                                                                                                                          NT-GYTA-32~36 n  32~36    6       6      10.2    107     600/1500      300/1000
                        NT-GYTS-2~30 n  2~30      5       6       9.8    108      600/1500     300/1000                                   NT-GYTA-38~60 n  38~60    5       12     10.4    110     600/1500      300/1000
                        NT-GYTS-32~36 n  32~36    6       6      10.4    129      600/1500     300/1000                                   NT-GYTA-62~72 n  62~72    6       12     11.4    130     600/1500      300/1000
                        NT-GYTS-38~60 n  38~60    5       12     10.6    132      600/1500     300/1000                                   NT-GYTA-74~96 n  74~96    8       12     13.6    165     600/1500      300/1000
                        NT-GYTS-62~72 n  62~72    6       12     12.1    161      600/1500     300/1000                                   NT-GYTA-98~120 n  98~120  10      12     14.8    195     600/2000      300/1000
                        NT-GYTS-74~96 n  74~96    8       12     13.6    198      600/1500     300/1000                                   NT-GYTA-122~144 n  122~144  12    12     16.4    236     600/2500      300/1000
                        NT-GYTS-98~120 n  98~120  10      12     15.4    260      600/1500     300/1000                                   NT-GYTA-146~216 n  146~216  18    12     16.4    232     600/2500      300/1000
                       NT-GYTS-122~144 n  122~144  12     12     17.2    286      600/1500     300/1000                                   NT-GYTA-218~288 n  218~288  24    12     20.0    300     1000/3000     300/1000
                       Note:                                                                                                            Note:
                       1.Suf x  n denotes  ber type and see details in Nitrotel  cable coding illustration.                             1.Suf x  n denotes  bre type and see details in Nitrotel  cable coding illustration.
                       2.The color arrangement of  ber and tube is speci ed in color identi cation table.                               2.The color arrangement of  bre and tube is speci ed in color identi cation table.                 & XPON  OPTICAL FIBER
                       3.The normal PE sheath thickness is 1.8mm.                                                                       3.The normal PE sheath thickness is 1.8mm.
                                                                                     Operation    -40℃~+70℃                                                                                           Operation    -40℃~+70℃
                       Characteristic                             Temperature requirement  Installation    -10℃~+70℃                    Characteristic                             Temperature requirement  Installation    -10℃~+70℃
                       Excellent  mechanical  and  temperature  performance                                                              Excellent  mechanical  and  temperature  performance
                       guaranteed by the accurate excess fiber length            Storage/transportation    -40℃~+70℃                     guaranteed by the accurate excess fiber length            Storage/transportation    -40℃~+70℃
                       Critical  protection  to  fibers,  based  on  the  excellent   Temperature cycling test  conform to IEC 794-1-F1  Critical  protection  to  fibers,  based  on  the  excellent   Temperature cycling test  conform to IEC 794-1-F1
                       hydrolysis  resistance  and  strength  performance  of  tube   Static                                             hydrolysis  resistance  and  strength  performance  of  tube   Static
                                                                                                                                                                                                          10 times of outer diameter
                                                                                         10 times of outer diameter
                       material and special filling compound filled in the tube   Dynamic                                                material and special filling compound filled in the tube  Dynamic
                       Excellent crush resistance and flexibility    Bending Radius      20 times of outer diameter                      Excellent ultraviolet prevention with PE sheath  Bending Radius  20 times of outer diameter
                       Excellent ultraviolet prevention with PE sheath                                                                   The following measures are taken to ensure the
                       The  following  measures  are  taken  to  ensure  the  water   Fig 2: High Fiber Count Cable                      water blocking performance of the cable:  Fig 2 and 3: High Fiber Count Cable


                       blocking performance of the cable:                                                                                - Single steel wire used as the central strength
                       - Single steel wire used as the central strength  member
                                                                                             Fiber                                       member                                               Fiber
                       - Special water-blocking filling compound in the loose tube                                                       - Special water-blocking filling compound in        PE Sheath
                       - 100% cable core filling                                             PSP                                                                                                                        Fiber
                                                                                       Cable Filling Compound                            theloose tube                                   Tube Filling Compound        PE Sheath
                       - PSP moisture barrier                                                                                            - 100% cable core filling                                                Cable Filling Compound
                                                                                           PE Sheath                                                                                         PE Sheath
                       Application: Duct/Aeria                                                                                                                                                                        PE Sheath
                                                                                           PE Sheath                                     - APL moisture barrier                          Cable Filling Compound   Tube Filling Compound
                                                                                           Loose Tube                                    Application: Duct/Aeria                               APL                      APL                 CABINETS
                                                                                       Tube Filling Compound                                                                                Loose Tube              Strength Member
                                                                                         Strength Member                                                                                   Strength Member            Loose Tube
             page  093                                                                                                                                                                                                        page  094
   46   47   48   49   50   51   52   53   54   55   56