Page 54 - Catalog
P. 54
NITROTEL PRODUCT INFORMATION STRUCTURED CABLING STRUCTURED CABLING NITROTEL PRODUCT INFORMATION & PATCH CABLE LAN CABLE
STRUCTURED CABLING STRUCTURED CABLING
OPTICAL FIBER OPTICAL FIBER
Dry Core Figure Cable with Steel Ta e G TF S Stranded Loose Tube Cable with Non etalli Central FACE PLATE
Strength Me ber G FT
Introduction Introduction
In the Nitrotel GYTF8S cable, single-mode/multimode bers In the GYFTY cable, single-mode/multimode fibers are HDPE Outer Sheath
are positioned in the loose tubes, which are made of high positioned in the loose tubes, which are made of high Filler
modulus plastic, while the loose tubes strand together Stranded Wires 7 x 1.6mm modulus plastic materials, while the loose tubes strand Water-blocking Compound
around metallic central strength member into a compact and HDPE Sheath together around non-metallic central strength member (FRP)
circular cable core, and the water-blocking yarns are into a compact and circular cable core. For certain high fibre FRP Strength Member
distributed into interstices of it. After a PSP is applied around Fiber count cables, the strength member would be covered with Loose Tube
the cable core, this part of cable accompanied with the polyethylene (PE). The water-blocking compound is Fiber
stranded wires as the supporting part are completed with a Loose Tube distributed into the interstices of the cable core. Then the Tube Filling Compound
HDPE sheath to be a gure-8 structure. This kind of cable is Tube Filling Compound
speci cally used for self supporting aerial installation. Wter Blocking Yarns cable is completed with a HDPE sheath. MODULES
PSP
PE Sheath
Strendth Member Fiber color code 9 10 11
Fiber color code 9 10 11 1 2 3 4 5 6 7 8 12
1 2 3 4 5 6 7 8 12 Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua
Fiber color in each tube starts from No. 1 Blue.
Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua
Fiber color in each tube starts from No. 1 Blue. Color codes for loose tube ller rod 9 10 11
Color codes for loose tube ller rod 9 10 11 1 2 3 4 5 6 7 8 12
1 2 3 4 5 6 7 8 12 Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua
Tube color in each layer starts from No. 1 Blue. If there are llers, the color is nature.
Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua
Tube color in each layer starts from No. 1 Blue. If there are llers, the color is nature.
Cable Type Tube Max. No. of Cable Cable Tensile Strength Crush Resistance
Fiber Count Fibers in Diameter Weight Long/ShortTerm Long/ShortTerm PATCH PANELS
Order Information and Characteristics of Optical Cables (increased by 2 bers) Fillers each Tube mm kg/km N N/100 mm
Cable Cable Type Tensile Strength Crush Resistance 6 300/1000
Cable Type Fiber NT-GYFY-2~36 n 2~36 6 10.6 92 400/1000
Diameter Weight Long/Short Term Long/Short Term 300/1000
(increased by 2 bers) Count NT-GYFY-38~60 n 38~60 5 12 11.2 102 400/1000
mm kg/km N N/100 mm
NT-GYFY-2~42 n 2~42 7 6 11.2 103 600/1500 300/1000
NTGYTC8S-2~30 n 2~30 9.6 x 21 270 3000/8000 300/1000
NT-GYFY-44~72 n 44~72 6 12 12.2 114 600/1500 300/1000
NTGYTC8S-32~36 n 32~36 10.2 x 21.6 285 3000/8000 300/1000
NT-GYFY-2~48 n 2~48 8 6 12.2 125 1000/3000 300/1000
NTGYTC8S-38~60 n 38~60 11.6 x 23 320 3000/8000 300/1000 NT-GYFY-50~96 n 50~96 8 12 13.6 160 1000/3000 300/1000
NTGYTC8S-62~72 n 62~72 12 x 23.4 340 3000/8000 300/1000 NT-GYFY-98~120 n 98~120 10 12 14.6 200 1000/3000 300/1000
NTGYTC8S-74~96 n 74~96 14.2 x 25.6 390 3000/8000 300/1000 NT-GYFY-122~144 n 122~144 12 12 16.8 235 1000/3000 300/1000
NTGYTC8S-98~120 n 98~120 16.0 x 27.4 430 3000/8000 300/1000 8 6
NT-GYFY-146~192 n 146~192 16.8 220 1000/3000 300/1000
NTGYTC8S-122~144 n 122~144 17.7 x 29.1 480 3000/8000 300/1000 12 12
Note: Note:
1. Suf x n denotes ber type and see details in Nitrotel cable coding illustration. 1.Suf x n denotes ber type and see details in Nitrotel cable coding illustration. & XPON OPTICAL FIBER
2. The color arrangement of ber and tube is speci ed in color identi cation table. 2.The color arrangement of ber and tube is speci ed in color identi cation table.
3. The normal PE sheath thickness is 1.8mm. 3.The normal PE sheath thickness is 2.0mm.
4. The installation span should not be more than 100m and the installation sag should not be less than 0.5%. Figure-8 cable with
other span and standard 0.5% sag is available on request. Characteristic
5. Dimensions of the gure-8 cable have close relationship with moulds and production process, the above-mentioned dimensions
are sub ect to actual dimensions Excellent mechanical and temperature performance
guaranteed by the accurate excess fiber length
Characteristic Critical protection to fibers, based on the excellent
hydrolysis resistance and strength performance of tube
Excellent mechanical and temperature performance material and special filling compound filled in the tube
Critical protection to fibers, based on the excellent hydrolysis Excellent ultraviolet prevention with PE sheath
resistance and strength performance of tube material and Excellent crush resistance and flexibility
special filling compound filled in the tube
The following measures are taken to ensure the water blocking The following measures are taken to ensure the water
performance of the cable: blocking performance of the cable:
- Single steel wire used as the central strength member - FRP used as the central strength member
- Special water-blocking filling compound in the loose tube - Special water-blocking filling compound in the loose tube
- 100% cable core filling - 100% cable core filling
- PSP moisture barrier Application: Duct/Aerial
Application: Duct/Aerial CABINETS
page 099 page 100