Page 13 - Catalog
P. 13
NITROTEL PRODUCT INFORMATION STRUCTURED CABLING STRUCTURED CABLING NITROTEL PRODUCT INFORMATION & PATCH CABLE LAN CABLE
STRUCTURED CABLING STRUCTURED CABLING
LAN CABLE LAN CABLE
U/UTP unshielded CAT E Twisted Pair Installation Cable F/UTP shielded CAT E Twisted Pair Installation Cable FACE PLATE
Application Application PET
Meets or exceeds requirements of ANSI/TIA-568-C.2 Copper Conductor Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition Copper Conductor
Category 5e and ISO 11801 2nd Edition Class D channel HDPE Insulation Class D Category 5e channel standards. HDPE Insulation
standards. Pair Exceeds requirements of ANSI/TIA-568-C.2 and IEC Aluminum Foil
Jacket Jacket
Meets or exceeds requirements of ANSI/TIA-568-C.2 61156-5 Category 5e component standards.
Rip Cord Drain Wire MODULES
and IEC 61156-5 Category 5e component standards. Meets requirements of IEEE 802.3af and IEEE 802.3at for
Rip Cord
Third party tested to Category 5e channel compliance. PoE applications.
Meets requirements of IEEE 802.3af and IEEE 802.3at for Foil shield reduces ingress of EMI interference to ensure
PoE applications. Conductor cable performance at high frequency levels. Conductor
Descending length cable markings enable easy identification Descending length cable markings enable easy identification
Conductor Solid Bare Copper 24AWG Conductor Solid Bare Copper 24AWG
of remaining cable which reduces installation time and cable of remaining cable which reduces installation time and cable
Insulation HDPE Insulation HDPE
scrap. scrap.
Total number of Total number of
Color Availability: Additional cable colors available. insulated conductors 8, twisted in 4 pairs Color Availability: Additional cable colors available. insulated conductors 8, twisted in 4 pairs
UL Verified. White-Blue/Blue,White-Orange/Orange UL Verified. White-Blue/Blue,White-Orange/Orange
Color code Color code
White-Green/Green,White-Brown/Brown White-Green/Green,White-Brown/Brown
Electrical Characteristics Individual pair shield None Electrical Characteristics Individual pair shield None
Overall shield None
Impedance: 1-100MHz 100±15(Ohms). Drain wire None Impedance: 1-100MHz 100±15(Ohms). Overall shield Aluminum foil, providing 100%
Rated Temperature: 75℃. Rated Temperature: 75℃. coverage, foil face out.
Drain wire None
DC Resistance Unbalance(%): Max 2.5. DC Resistance Unbalance(%): Max 2.5. PATCH PANELS
Order information (Part Number)
DC Resistance 20℃: 9.5(Ohms/100m). DC Resistance 20℃: 9.5(Ohms/100m).
NTNC5E_ _ - _ Order information (Part Number)
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M). Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Insulation Resistance: >5000MΩ*Km. Insulation Resistance: >5000MΩ*Km. NTNC5E_ _FTP-_
Dielectric strength: DC 2500V 2S. Jacket Color Dielectric strength: DC 2500V 2S.
BU Item Outer Jacket Overall diameter(mm) Jacket Color
RD
RD
BK
GY P CMP 5.1±0.2 BU Item Outer Jacket Overall diameter(mm)
C CM 5.1±0.2 P CMP 6.3±0.2
BK
YL
WH GY
Blank CMR 5.1±0.2 C CM 6.3±0.2
YL
GN PR L LSZH 5.1±0.2 WH Blank CMR 6.3±0.2
E LDPE 5.1±0.2 GN PR L LSZH 6.3±0.2
Nominal Transmission Characteristics E LDPE 6.3±0.2
Nominal Transmission Characteristics
Frequency RL (min) IL(max) DOP(max) Delay Skew NEXT (min) PSNE T ACR-F PSACR-F
(max) (min) (min) (min) Frequency RL (min) IL(max) DOP(max) Delay Skew NEXT (min) PSNE T ACR-F PSACR-F & XPON OPTICAL FIBER
(MH)z (dB) ( dB/100m) ( ns/100m) ( ns/100m) (dB) (dB) ( dB/100m) ( dB/100m) (max) (min) (min) (min)
(MH)z (dB) ( dB/100m) ( ns/100m) ( ns/100m) (dB) (dB) ( dB/100m) ( dB/100m)
1 20.0 2.2 570 45 65 62 61 61
4 23.0 4 2 552 45 56 53 48 48 1 20.0 2.2 570 45 65 62 61 61
10 25.0 6 5 545 45 50 47 41 41 4 23.0 4 2 552 45 56 53 48 48
16 25.0 8 4 543 45 47 44 36 36 10 25.0 6 5 545 45 50 47 41 41
20 25.0 9 3 542 45 45 42 34 34 16 25.0 8 4 543 45 47 44 36 36
20 25.0 9 3 542 45 45 42 34 34
31.25 23.6 11 6 540 45 42 39 31 31
62.5 21.5 17 0 538 45 38 35 25 25 31.25 23.6 11 6 540 45 42 39 31 31
100 20.1 22 0 537 45 35 32 21 21 62.5 21.5 17 0 538 45 38 35 25 25
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested. 100 20.1 22 0 537 45 35 32 21 21
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.