Page 16 - Catalog
P. 16
NITROTEL PRODUCT INFORMATION STRUCTURED CABLING STRUCTURED CABLING NITROTEL PRODUCT INFORMATION & PATCH CABLE LAN CABLE
STRUCTURED CABLING STRUCTURED CABLING
LAN CABLE LAN CABLE
F/UTP steel wire su ort shielded CAT E Twisted Pair U/UTP unshielded CAT E Twisted Pair FACE PLATE
Installation Cable Installation Cable
Application Application
Exceeds ANSI/TIA-568-C.2 and ISO 11801 2nd Edition Meets or exceeds requirements of ANSI/TIA-568-C.2
Class D Category 5e channel standards. PET Category 5e and ISO 11801 2nd Edition Class D channel Copper Conductor
Copper Conductor HDPE Insulation
Exceeds requirements of ANSI/TIA-568-C.2 and IEC standards.
HDPE Insulation
61156-5 Category 5e component standards. Meets or exceeds requirements of ANSI/TIA-568-C.2 Filler
Aluminum Foil Rip Cord
Meets requirements of IEEE 802.3af and IEEE 802.3at for and IEC 61156-5 Category 5e component standards. MODULES
Jacket Jacket
PoE applications. Drain Wire Third party tested to Category 5e channel compliance.
Foil shield reduces ingress of EMI interference to ensure Rip Cord Meets requirements of IEEE 802.3af and IEEE 802.3at for
cable performance at high frequency levels. PoE applications. Conductor
Descending length cable markings enable easy identification Conductor Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable of remaining cable which reduces installation time and cable Conductor Solid Bare Copper 24AWG
Conductor Solid Bare Copper 24AWG
scrap. scrap. Insulation HDPE
Insulation HDPE
Color Availability: Additional cable colors available. Color Availability: Additional cable colors available. Total number of 16, twisted in 8 pairs
Total number of insulated conductors
UL Verified. insulated conductors 8, twisted in 4 pairs Patent products: CN201020293718 1.
White/Blue,White/Orange,White/Green,
White-Blue/Blue,White-Orange/Orange UL Verified. Color code White/Brown,White/Grey
Color code
White-Green/Green,White-Brown/Brown Red/Blue,Red/Orange,Red/Green
Electrical Characteristics Individual pair shield None Individual pair shield None
Electrical Characteristics Overall shield None
Impedance: 1-100MHz 100±15(Ohms). Overall shield Aluminum foil, providing 100% Drain wire None
Rated Temperature: 75℃. coverage, foil face out. Impedance: 1-100MHz 100±15(Ohms).
Drain wire None PATCH PANELS
DC Resistance Unbalance(%): Max 2.5. Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5. Order information (Part Number)
DC Resistance 20℃: 9.5(Ohms/100m).
DC Resistance 20℃: 9.5(Ohms/100m).
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M). NTNC5E_ _8PR -_
Order information ( a t N m
Insulation Resistance: >5000MΩ*Km. Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Dielectric strength: DC 2500V 2S. Item Outer Jacket Overall diameter(mm) Insulation Resistance: >5000MΩ*Km. Jacket Color
Dielectric strength: DC 2500V 2S.
NTNC5EBKFTP-F8 LDPE (6.3+2.3)±0.3
RD
BU Item Outer Jacket Overall diameter(mm)
GY P CMP 8.1±0.2
BK
C CM 8.1±0.2
YL
WH
Blank CMR 8.1±0.2
Nominal Transmission Characteristics GN PR L LSZH 8.1±0.2
E LDPE 8.1±0.2
Frequency RL (min) IL(max) DOP(max) Delay Skew NEXT (min) PSNE T ACR-F PSACR-F Nominal Transmission Characteristics
(max) (min) (min) (min)
(MH)z (dB) ( dB/100m) ( ns/100m) ( ns/100m) (dB) (dB) ( dB/100m) ( dB/100m) Delay Skew PSNE T ACR-F PSACR-F
1 20.0 2.2 570 45 65 62 61 61 Frequency RL (min) IL(max) DOP(max) NEXT (min) & XPON OPTICAL FIBER
(max) (min) (min) (min)
4 23.0 4 2 552 45 56 53 48 48 (MH)z (dB) ( dB/100m) ( ns/100m) ( ns/100m) (dB) (dB) ( dB/100m) ( dB/100m)
10 25.0 6 5 545 45 50 47 41 41
1 20.0 2.2 570 45 65 62 61 61
16 25.0 8 4 543 45 47 44 36 36
4 23.0 4 2 552 45 56 53 48 48
20 25.0 9 3 542 45 45 42 34 34
10 25.0 6 5 545 45 50 47 41 41
31.25 23.6 11 6 540 45 42 39 31 31
16 25.0 8 4 543 45 47 44 36 36
62.5 21.5 17 0 538 45 38 35 25 25
20 25.0 9 3 542 45 45 42 34 34
100 20.1 22 0 537 45 35 32 21 21
31.25 23.6 11 6 540 45 42 39 31 31
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
62.5 21.5 17 0 538 45 38 35 25 25
100 20.1 22 0 537 45 35 32 21 21
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.