Page 15 - Catalog
P. 15
NITROTEL PRODUCT INFORMATION STRUCTURED CABLING STRUCTURED CABLING NITROTEL PRODUCT INFORMATION & PATCH CABLE LAN CABLE
STRUCTURED CABLING STRUCTURED CABLING
LAN CABLE LAN CABLE
U/UTP unshielded CAT E Twisted Pair Installation Cable U/UTP steel wire su ort unshielded CAT E Twisted FACE PLATE
Pair Installation Cable
Pair Installation Cable
Application Application
Meets or exceeds requirements of ANSI/TIA-568-C.2 Meets or exceeds requirements of ANSI/TIA-568-C.2
Category 5e and ISO 11801 2nd Edition Class D channel Category 5e and ISO 11801 2nd Edition Class D channel
standards. standards.
Copper Conductor Copper Conductor
Meets or exceeds requirements of ANSI/TIA-568-C.2 HDPE Insulation Meets or exceeds requirements of ANSI/TIA-568-C.2 and HDPE Insulation
and IEC 61156-5 Category 5e component standards. Pair IEC 61156-5 Category 5e component standards. Pair MODULES
Third party tested to Category 5e channel compliance. Jacket Third party tested to Category 5e channel compliance. Jacket
Meets requirements of IEEE 802.3af and IEEE 802.3at for Rip Cord Meets requirements of IEEE 802.3af and IEEE 802.3at for Rip Cord
PoE applications. PoE applications.
Descending length cable markings enable easy identification Descending length cable markings enable easy identification
of remaining cable which reduces installation time and cable Conductor of remaining cable which reduces installation time and cable
Conductor
scrap. Conductor Solid Bare Copper 24AWG scrap.
Color Availability: Additional cable colors available. Insulation HDPE Color Availability: Additional cable colors available. Conductor Solid Bare Copper 24AWG
Patent products: CN200920124768 4. Total number of 2x8, twisted in 2x4 pairs UL Verified. Insulation HDPE
insulated conductors
UL Verified. Total number of 8, twisted in 4 pairs
White-Blue/Blue,White-Orange/Orange insulated conductors
Color code
White-Green/Green,White-Brown/Brown White-Blue/Blue,White-Orange/Orange
Color code
Individual pair shield None White-Green/Green,White-Brown/Brown
Individual pair shield None
Overall shield None
Drain wire None Overall shield None
Electrical Characteristics Electrical Characteristics Drain wire None PATCH PANELS
Impedance: 1-100MHz 100±15(Ohms). Impedance: 1-100MHz 100±15(Ohms).
Rated Temperature: 75℃. Order information (Part Number) Rated Temperature: 75℃.
DC Resistance Unbalance(%): Max 2.5. NTNC5E_ _2 -_ DC Resistance Unbalance(%): Max 2.5. Order information ( a t N m
DC Resistance 20℃: 9.5(Ohms/100m). DC Resistance 20℃: 9.5(Ohms/100m).
Item Outer Jacket Overall diameter(mm)
Pair-to-Gruond Capacitance Unbalance: 330(pF/100M). Pair-to-Gruond Capacitance Unbalance: 330(pF/100M).
Jacket Color NTNC5EBK-F8 LDPE (5.1+2.3)±0.3
Insulation Resistance: >5000MΩ*Km. Insulation Resistance: >5000MΩ*Km.
RD
BU Item Outer Jacket Overall diameter(mm)
Dielectric strength: DC 2500V 2S. Dielectric strength: DC 2500V 2S.
BK
GY P CMP (5.2+5.2)+/-0.3
C CM (5.2+5.2)+/-0.3
YL
WH
Blank CMR (5.2+5.2)+/-0.3 Nominal Transmission Characteristics
GN PR L LSZH (5.2+5.2)+/-0.3
E LDPE (5.2+5.2)+/-0.3 Frequency RL (min) IL(max) DOP(max) Delay Skew NEXT (min) PSNE T ACR-F PSACR-F
Nominal Transmission Characteristics (max) (min) (min) (min)
(MH)z (dB) ( dB/100m) ( ns/100m) ( ns/100m) (dB) (dB) ( dB/100m) ( dB/100m) & XPON OPTICAL FIBER
Frequency RL (min) IL(max) DOP(max) Delay Skew NEXT (min) PSNE T ACR-F PSACR-F 1 20.0 2.2 570 45 65 62 61 61
(max) (min) (min) (min) 4 23.0 4 2 552 45 56 53 48 48
(MH)z (dB) ( dB/100m) ( ns/100m) ( ns/100m) (dB) (dB) ( dB/100m) ( dB/100m) 10 25.0 6 5 545 45 50 47 41 41
1 20.0 2.2 570 45 65 62 61 61 16 25.0 8 4 543 45 47 44 36 36
4 23.0 4 2 552 45 56 53 48 48 20 25.0 9 3 542 45 45 42 34 34
10 25.0 6 5 545 45 50 47 41 41 31.25 23.6 11 6 540 45 42 39 31 31
16 25.0 8 4 543 45 47 44 36 36 62.5 21.5 17 0 538 45 38 35 25 25
20 25.0 9 3 542 45 45 42 34 34 100 20.1 22 0 537 45 35 32 21 21
31.25 23.6 11 6 540 45 42 39 31 31 Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested.
62.5 21.5 17 0 538 45 38 35 25 25
100 20.1 22 0 537 45 35 32 21 21
Note: The above transmission performance for the 100M, 20 ± 2℃ under the conditions tested. CABINETS
page 019 page 020